Advertising

Installation Instructions for

Heating & Air Conditioning

1F79

Non- Programmable

Single Stage. Non-Programmable T h e r m o s t a t. Single Stage. 2 Programs T h e r m o s t a t. Single Stage/Heat. Non-Programmable T h e r m o s t a t. 70Series ™ White-Rodgers. E C O N O M Y. The Digital Thermostat That Builds Your Business and Flexes Your Inventory. 70series, Single stage, White-rodgers. Read online or download PDF. White Rodgers 1E78-140 User Manual. Manuals Directory ManualsDir.com - online owner manuals library. (1E78-151) Millivolt compatible. Get White Rodgers 1F78-151 Use and Care Manual. Get all White Rodgers manuals! Press PRGM and R UN buttons at the same time.

Heat Pump Thermostat

CONTENTS

Preparations ......................... 1

Thermostat Details .................... 1

Removing Old Thermostat ............. 1-2

Mounting and Wiring ................. 2-3

Check Thermostat Operation ........... 4-5

Specifications ........................ 5

Troubleshooting ..................... 5-6

PREPARATIONS

THERMOSTAT DETAILS

REMOVING OLD THERMOSTAT

Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.

1. Remove Old Thermostat: A standard heat/cool thermostat

consists of three basic parts:

a. The cover, which may be either a snap-on or hinge type.

b. The base, which is removed by loosening all captive screws.

c. The switching subbase, which is removed by unscrewing

the mounting screws that hold it on the wall or adaptor plate.

2. Shut off electricity at the main fuse box until installation is

complete. Ensure that electrical power is disconnected.

3. Remove the front cover of the old thermostat. With wires still

attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.

4. Identify each wire attached to the old thermostat using the

labels enclosed with the new thermostat.

5. Disconnect the wires from the old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

6. Install new thermostat using the following procedures.

To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.

CAUTION

!

Printed in U.S.A.

PART NO. 37-6499A

0342

WHITE-RODGERS
EMERSON ELECTRIC CO.
ST. LOUIS, MISSOURI

www.white-rodgers.com

Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage.

Assemble tools required as shown below.

YOUR THERMOSTAT REPLACES

1

2

3

WIRE CUTTER/STRIPPER

HAND OR POWER
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED

FLAT BLADE SCREWDRIVER

SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL—

THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY

Figure 1. Thermostat base

W905

Clip for

Slow Cycle

W904

Clip for

Celsius

Mounting

hole

W906 for Emergency

Heat Second Stage

Fan Control

O/B

Terminal

Switches

Selection

Mounting

hole

Description

Heat Pump (No Aux or Emergency Heat)

Yes

Heat Pump (with Aux or Emergency Heat)

Yes

Standard Heat & Cooling Systems

No

Standard Heat Only Systems

No

Millivolt Heat Only Systems – Floor or Wall Furnaces

No

Standard Central Air Conditioning

No

Gas or Oil Heat

No

Electric Furnace

No

Hydronic (Hot Water) Zone Heat – 2 Wires

No

Hydronic (Hot Water) Zone Heat – 3 Wires

No

Advertising
Popular Brands
Popular manuals

Single Stage

White-Rodgers

Digital 5/2 Day

Programmable and

Non-Programmable

70 Series

Battery

E C O N O M Y

1E78-144

1E78-151

The Digital Thermostat That Builds

1E78-140

Your Business and Flexes Your Inventory.

The new vertical 70 Seriesthermostats build your new construction business. It's the first series of flexible thermostats enabling customers to wire and mount one subbase for use with the temporary new construction thermostat and easily snap on an upgrade to any 1E78 digital model upon building completion. The vertical 70 Series low-profile design blends narrow width with new home decors. The universal subbase, for use with all 1E78 models, is designed to mount on a 2' x 4' junction box or directly to the wall. There is also an optional wallplate for use in retro-fit applications. The 70 Series thermostats are battery powered, making them easy to install and compatible with most heating and cooling systems. The vertical 70 Series is perfect for new construction customers who want a quick and easy transition to job completion.

Programming

Choice of 5/2 day programming (weekday/weekend) or non-programmable

4 time and 4 temperature settings per program for heating and cooling (1E78-151)

Energy savings up to 33%

Display

Large, easy-to-read thermostat display

New — Lighted display for easier low-light viewing

BI

Y LL

G

S

E

O

S

3

E

C

3

D

%

U

ENERGY

SAVER

Comfort & Convenience

Electronic temperature accuracy Adjustable room temperature calibration

Performance

B & O terminals

Meets California Building Code, Title 24 (1E78-151)

Millivolt compatible

Battery-powered thermostat for maximum compatibility (2 “AAA” Energizer® batteries included)

Maintains room temperature differential within +/- 1 degree

ACCURACY

OPTIMUM COMFORT

AND PERFORMANCE

1E78-151

Single Stage

2 Programs

T h e r m o s t a t

1E78-144

Single Stage

Non-Programmable

T h e r m o s t a t

1E78-140

Single Stage/Heat

Non-Programmable

T h e r m o s t a t

Single Stage

White-Rodgers

Digital 5/2 Day

Programmable and

Non-Programmable

70 Series

Battery

E C O N O M Y

Dimensions

3.25'W x 5.3'H x 1.1'D

Allen and heath zed 428. ZED effects are easily controlled using 3 buttons with 9 display LEDs.

Electrical Specifications

Rating

0 to 30 VAC, 50/60 Hz or DC

White rodgers 1e78 151 user manual download

0.05 to 1.0 Amp (load per terminal)

1.5 Amps maximum load (all terminals combined)

Standard Systems

Single stage gas, oil, electric

Single stage heat pump (1E78-151 and 1E78-144)

Millivolt compatible

Terminal Designations

White Rodgers 1e78 151 User Manual Pdf

1E78-151, 1E78-144 and F4-1748

Thermal Specifications

Setpoint Temperature Range: 45° to 90°F (7° to 32°C)

Rated Differential: 0.6° to 1.9°F with adjustable anticipation

Operating Ambient Temperature: 32° to 105°F (0° to 40°C)

Operating Humidity Range: 90% non-condensing maximum

Shipping Temperature Range: -4° to 150°F (-20° to 65°C)

1E78-140

Accessories

Wall Plate F61-2593 (4.5'W x 6.6'H)

Subbase F4-1748 (3.25'W x 5.3'H)

“New Construction Stat” 1D78-140 with heat only 65° setpoint

Thermostat Guard F29-0143

(For additional guard options refer to White-Rodgers catalog.)

For Additional Information

Visit www.white-rodgers.com

“New Construction Stat”

Wall Plate F61-2593

F4-1748 Subbase mounted on 2' x 4' Junction

1D78-140

Box with 1D78-140 “New Construction Stat”

Manual For White Rodgers Thermostat

Application Guide

Series

System

Programs

Power Source

90

- Premium

Single Stage

7 day

Power stealing w/battery back-up

80

- Standard

Multi-Stage

5/1/1 day

Hardwired/battery

Heat Pump

5/2 day

Battery

70 - Economy

Non-programmable

Hardwired

Controlling Indoor Comfort Worldwide

Since 1937

St. Louis, Missouri

Markham, Ontario

WR-6526

314-577-1300

905-201-4701

www.white-rodgers.com

1E78-151

Single Stage

White Rodgers 1e78-151 Manual

2 Programs

T h e r m o s t a t

1E78-144

Single Stage

Non-Programmable

T h e r m o s t a t

1E78-140

Single Stage/Heat

Non-Programmable

White Rodgers Thermostat Manual Pdf

T h e r m o s t a t

The Emerson logo is a trademark and a service mark of Emerson Electric Co.

To continue the download you need to go through the captcha:

White Rodgers 1e78 151 User Manual Free