- White Rodgers 1e78 151 User Manual Pdf
- Manual For White Rodgers Thermostat
- White Rodgers 1e78-151 Manual
- White Rodgers Thermostat Manual Pdf
- White Rodgers 1e78 151 User Manual Free
Installation Instructions for
Heating & Air Conditioning
1F79
Non- Programmable
Single Stage. Non-Programmable T h e r m o s t a t. Single Stage. 2 Programs T h e r m o s t a t. Single Stage/Heat. Non-Programmable T h e r m o s t a t. 70Series ™ White-Rodgers. E C O N O M Y. The Digital Thermostat That Builds Your Business and Flexes Your Inventory. 70series, Single stage, White-rodgers. Read online or download PDF. White Rodgers 1E78-140 User Manual. Manuals Directory ManualsDir.com - online owner manuals library. (1E78-151) Millivolt compatible. Get White Rodgers 1F78-151 Use and Care Manual. Get all White Rodgers manuals! Press PRGM and R UN buttons at the same time.
Heat Pump Thermostat
CONTENTS
Preparations ......................... 1
Thermostat Details .................... 1
Removing Old Thermostat ............. 1-2
Mounting and Wiring ................. 2-3
Check Thermostat Operation ........... 4-5
Specifications ........................ 5
Troubleshooting ..................... 5-6
PREPARATIONS
THERMOSTAT DETAILS
REMOVING OLD THERMOSTAT
Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.
1. Remove Old Thermostat: A standard heat/cool thermostat
consists of three basic parts:
a. The cover, which may be either a snap-on or hinge type.
b. The base, which is removed by loosening all captive screws.
c. The switching subbase, which is removed by unscrewing
the mounting screws that hold it on the wall or adaptor plate.
2. Shut off electricity at the main fuse box until installation is
complete. Ensure that electrical power is disconnected.
3. Remove the front cover of the old thermostat. With wires still
attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.
4. Identify each wire attached to the old thermostat using the
labels enclosed with the new thermostat.
5. Disconnect the wires from the old thermostat one at a time. DO
NOT LET WIRES FALL BACK INTO THE WALL.
6. Install new thermostat using the following procedures.
To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.
CAUTION
!
Printed in U.S.A.
PART NO. 37-6499A
0342
WHITE-RODGERS
EMERSON ELECTRIC CO.
ST. LOUIS, MISSOURI
www.white-rodgers.com
Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage.
Assemble tools required as shown below.
YOUR THERMOSTAT REPLACES
1
2
3
WIRE CUTTER/STRIPPER
HAND OR POWER
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED
FLAT BLADE SCREWDRIVER
SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL—
THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY
Figure 1. Thermostat base
W905
Clip for
Slow Cycle
W904
Clip for
Celsius
Mounting
hole
W906 for Emergency
Heat Second Stage
Fan Control
O/B
Terminal
Switches
Selection
Mounting
hole
Description
Heat Pump (No Aux or Emergency Heat)
Yes
Heat Pump (with Aux or Emergency Heat)
Yes
Standard Heat & Cooling Systems
No
Standard Heat Only Systems
No
Millivolt Heat Only Systems – Floor or Wall Furnaces
No
Standard Central Air Conditioning
No
Gas or Oil Heat
No
Electric Furnace
No
Hydronic (Hot Water) Zone Heat – 2 Wires
No
Hydronic (Hot Water) Zone Heat – 3 Wires
No
Single Stage |
White-Rodgers |
Digital 5/2 Day |
|
Programmable and |
™ |
Non-Programmable |
70 Series |
Battery |
|
E C O N O M Y |
1E78-144
1E78-151 |
|
The Digital Thermostat That Builds |
1E78-140 |
Your Business and Flexes Your Inventory. |
The new vertical 70 Series™ thermostats build your new construction business. It's the first series of flexible thermostats enabling customers to wire and mount one subbase for use with the temporary new construction thermostat and easily snap on an upgrade to any 1E78 digital model upon building completion. The vertical 70 Series low-profile design blends narrow width with new home decors. The universal subbase, for use with all 1E78 models, is designed to mount on a 2' x 4' junction box or directly to the wall. There is also an optional wallplate for use in retro-fit applications. The 70 Series thermostats are battery powered, making them easy to install and compatible with most heating and cooling systems. The vertical 70 Series is perfect for new construction customers who want a quick and easy transition to job completion.
Programming
Choice of 5/2 day programming (weekday/weekend) or non-programmable
4 time and 4 temperature settings per program for heating and cooling (1E78-151)
Energy savings up to 33%
Display
Large, easy-to-read thermostat display
New — Lighted display for easier low-light viewing
BI |
||
Y LL |
||
G |
S |
|
E |
O |
|
S |
3 |
|
E |
||
C |
3 |
|
D |
% |
|
U |
||
ENERGY |
||
SAVER |
Comfort & Convenience
Electronic temperature accuracy Adjustable room temperature calibration
Performance
B & O terminals
Meets California Building Code, Title 24 (1E78-151)
Millivolt compatible
Battery-powered thermostat for maximum compatibility (2 “AAA” Energizer® batteries included)
Maintains room temperature differential within +/- 1 degree
ACCURACY
OPTIMUM COMFORT
AND PERFORMANCE
1E78-151
Single Stage
2 Programs
T h e r m o s t a t
1E78-144
Single Stage
Non-Programmable
T h e r m o s t a t
1E78-140
Single Stage/Heat
Non-Programmable
T h e r m o s t a t
Single Stage |
White-Rodgers |
|
Digital 5/2 Day |
||
Programmable and |
™ |
|
Non-Programmable |
70 Series |
|
Battery |
||
E C O N O M Y |
Dimensions
3.25'W x 5.3'H x 1.1'D
Allen and heath zed 428. ZED effects are easily controlled using 3 buttons with 9 display LEDs.
Electrical Specifications
Rating
0 to 30 VAC, 50/60 Hz or DC
0.05 to 1.0 Amp (load per terminal)
1.5 Amps maximum load (all terminals combined)
Standard Systems
Single stage gas, oil, electric
Single stage heat pump (1E78-151 and 1E78-144)
Millivolt compatible
Terminal Designations
White Rodgers 1e78 151 User Manual Pdf
1E78-151, 1E78-144 and F4-1748
Thermal Specifications
Setpoint Temperature Range: 45° to 90°F (7° to 32°C)
Rated Differential: 0.6° to 1.9°F with adjustable anticipation
Operating Ambient Temperature: 32° to 105°F (0° to 40°C)
Operating Humidity Range: 90% non-condensing maximum
Shipping Temperature Range: -4° to 150°F (-20° to 65°C)
1E78-140
Accessories
Wall Plate F61-2593 (4.5'W x 6.6'H)
Subbase F4-1748 (3.25'W x 5.3'H)
“New Construction Stat” 1D78-140 with heat only 65° setpoint
Thermostat Guard F29-0143
(For additional guard options refer to White-Rodgers catalog.)
For Additional Information
Visit www.white-rodgers.com
“New Construction Stat” |
Wall Plate F61-2593 |
F4-1748 Subbase mounted on 2' x 4' Junction |
1D78-140 |
Box with 1D78-140 “New Construction Stat” |
Manual For White Rodgers Thermostat
Application Guide
Series |
System |
Programs |
Power Source |
|||||
90 |
- Premium |
Single Stage |
7 day |
Power stealing w/battery back-up |
||||
80 |
- Standard |
Multi-Stage |
5/1/1 day |
Hardwired/battery |
||||
Heat Pump |
5/2 day |
Battery |
||||||
70 - Economy |
Non-programmable |
Hardwired |
Controlling Indoor Comfort Worldwide
Since 1937
St. Louis, Missouri |
Markham, Ontario |
|
WR-6526 |
314-577-1300 |
905-201-4701 |
www.white-rodgers.com |
1E78-151
Single Stage
White Rodgers 1e78-151 Manual
2 Programs
T h e r m o s t a t
1E78-144
Single Stage
Non-Programmable
T h e r m o s t a t
1E78-140
Single Stage/Heat
Non-Programmable
White Rodgers Thermostat Manual Pdf
T h e r m o s t a t
The Emerson logo is a trademark and a service mark of Emerson Electric Co.